Home |
Search |
Today's Posts |
![]() |
|
uk.sci.weather (UK Weather) (uk.sci.weather) For the discussion of daily weather events, chiefly affecting the UK and adjacent parts of Europe, both past and predicted. The discussion is open to all, but contributions on a practical scientific level are encouraged. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#11
![]() |
|||
|
|||
![]()
Keith (Southend) wrote:
On 31/12/2016 14:59, JohnD wrote: "Norman Lynagh" wrote in message ... I solved the problem by replacing the temp/RH sensor with one of the new 'enhanced' sensors which are supposedly more accurate. It has all been working fine since then. If anyone wants more detail on the digital T/H sensors in the Davis VP2 and Vue stations then a detailed description is included in the following topic on the Davis knowledgebase that we maintain: http://www.manula.com/manuals/pws/da...ure-humidity-g eneral NB1 This isn't really intended as light reading but the details are there if you need them! NB2 All pre-2006 Davis stations (ie WMII / VP1 / early VP2 models) used an analogue T/H assembly which, sad to say, is no longer available from Davis. Supplies were maintained well beyond the 5-year period which is Davis policy for the continued availability of spares after the end of production of particular models, but that stockpile is now totally exhausted. Occasionally spares may turn up eg on eBay and similar sites. John Dann www.weatherstations.co.uk Sounds like my options a 1. Forget about the hunidity/dew point 2. Get a new system Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. Might be worth a try, Keith. -- Norman Lynagh Tideswell, Derbyshire 303m a.s.l. http://peakdistrictweather.org @TideswellWeathr |
#12
![]() |
|||
|
|||
![]()
JohnD wrote:
"Norman Lynagh" wrote in message ... I solved the problem by replacing the temp/RH sensor with one of the new 'enhanced' sensors which are supposedly more accurate. It has all been working fine since then. If anyone wants more detail on the digital T/H sensors in the Davis VP2 and Vue stations then a detailed description is included in the following topic on the Davis knowledgebase that we maintain: http://www.manula.com/manuals/pws/da...e-humidity-gen eral NB1 This isn't really intended as light reading but the details are there if you need them! That's an interesting article, John. I hadn't realised it was all so complicated. I recently bought the 7346.174 version to replace my faulty one. I'm very happy with the replacement. Fitting it was no great problem though it is useful to have a second person to hold the 'pile of plates' when the temperature screen is dismantled. I also took the opportunity to give the whole thing a good clean. -- Norman Lynagh Tideswell, Derbyshire 303m a.s.l. http://peakdistrictweather.org @TideswellWeathr |
#13
![]() |
|||
|
|||
![]()
On 31/12/2016 16:05, Norman Lynagh wrote:
Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. Might be worth a try, Keith. I'm struggling to find the page sensor in question for the WMII, is it this one? http://www.weatherspares.co.uk/repla...chip-342-p.asp I'm sure it's linked, but external temperature seems ok. Thanks Norman. -- Keith (Southend) "Weather Home & Abroad" http://www.southendweather.net Twitter:@SS9Weatherman |
#14
![]() |
|||
|
|||
![]()
On 31/12/2016 17:04, Keith (Southend) wrote:
On 31/12/2016 16:05, Norman Lynagh wrote: Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. Might be worth a try, Keith. I'm struggling to find the page sensor in question for the WMII, is it this one? http://www.weatherspares.co.uk/repla...chip-342-p.asp I'm sure it's linked, but external temperature seems ok. Thanks Norman. Also never opened up the white box part inside the enclosure, is it a soldering job changing this sensor? -- Keith (Southend) "Weather Home & Abroad" http://www.southendweather.net Twitter:@SS9Weatherman |
#15
![]() |
|||
|
|||
![]()
Keith (Southend) wrote:
Houston, I think we have a problem! I can't beleive the humidity is still 100% outside, but it's been stuck on it since yesterday evening. Any ideas/solutions? Humidity here has been = 98% for the last 5 days. Maybe it's right? Check around nearby stations. -- Brian Wakem Lower Bourne, Farnham, Surrey http://www.brianwakem.co.uk/weather Live obs @ 17:11:34 : 5.5C, DP 5.5C, RH 100%, 0.0 mm |
#16
![]() |
|||
|
|||
![]()
"Norman Lynagh" wrote in message ...
Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. ================================================== ============ That's fine for a pre-2006 VP2 and IIRC a VP1, but the WMII T/H sensor assembly is a different item again I'm afraid. TBH I've never really looked in detail, but it may be that the actual 2-pin humidity sensor element from a VP1 board might fit in a WMII assembly. But even if that's the case there's no guarantee that it will restore correct readings. On a WMII, there's no obvious reason why the OAT shouldn't continue to work OK even if the RH is faulty. But I'm guessing that the WMII is now some 12-15 years old and there comes a point where station renewal is the only real option. |
#17
![]() |
|||
|
|||
![]()
Keith (Southend) wrote:
On 31/12/2016 16:05, Norman Lynagh wrote: Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. Might be worth a try, Keith. I'm struggling to find the page sensor in question for the WMII, is it this one? http://www.weatherspares.co.uk/repla...rehumidity-sen sor-chip-342-p.asp I'm sure it's linked, but external temperature seems ok. Thanks Norman. Hi Keith, No, it's this one (watch the line-wrap) http://www.weatherspares.co.uk/davis...dity-analogue- sensor-and-pre-2006-pro2-models-414-p.asp -- Norman Lynagh Tideswell, Derbyshire 303m a.s.l. http://peakdistrictweather.org @TideswellWeathr |
#18
![]() |
|||
|
|||
![]()
JohnD wrote:
"Norman Lynagh" wrote in message ... Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. ================================================== ============ That's fine for a pre-2006 VP2 and IIRC a VP1, but the WMII T/H sensor assembly is a different item again I'm afraid. TBH I've never really looked in detail, but it may be that the actual 2-pin humidity sensor element from a VP1 board might fit in a WMII assembly. But even if that's the case there's no guarantee that it will restore correct readings. On a WMII, there's no obvious reason why the OAT shouldn't continue to work OK even if the RH is faulty. But I'm guessing that the WMII is now some 12-15 years old and there comes a point where station renewal is the only real option. Ah, yes. I see what you mean, John. Sorry, Keith, I seem to have been leading you up a blind alley :-( -- Norman Lynagh Tideswell, Derbyshire 303m a.s.l. http://peakdistrictweather.org @TideswellWeathr |
#19
![]() |
|||
|
|||
![]()
On 31/12/2016 17:33, Norman Lynagh wrote:
JohnD wrote: "Norman Lynagh" wrote in message ... Weatherspares.co.uk are currently selling the pre-2006 analogue T/H sensors for £65. They say the stock is very limited and when they're gone they're gone. ================================================== ============ That's fine for a pre-2006 VP2 and IIRC a VP1, but the WMII T/H sensor assembly is a different item again I'm afraid. TBH I've never really looked in detail, but it may be that the actual 2-pin humidity sensor element from a VP1 board might fit in a WMII assembly. But even if that's the case there's no guarantee that it will restore correct readings. On a WMII, there's no obvious reason why the OAT shouldn't continue to work OK even if the RH is faulty. But I'm guessing that the WMII is now some 12-15 years old and there comes a point where station renewal is the only real option. Ah, yes. I see what you mean, John. Sorry, Keith, I seem to have been leading you up a blind alley :-( No worries Norman, my WMII the first data on my logger is 20:30 15/10/99 so that's over 17 years now! That Steam Train has been heading for a cliff for some time now, I think living in the soft SE has meant that it doesn't get as *weatherered* as some of you up north ;-) It may be time to think seriously about my options in 2017. -- Keith (Southend) "Weather Home & Abroad" http://www.southendweather.net Twitter:@SS9Weatherman |
#20
![]() |
|||
|
|||
![]()
On Sat, 31 Dec 2016 14:33:49 +0000, "Keith (Southend)"
wrote: Oh S&^t. The temperature sensor will continue to work and, from memory, it's relatively easy to modify the software to eliminate the humidity readings and displays - I think. -- Alan White Mozilla Firefox and Forte Agent. By Loch Long, twenty-eight miles NW of Glasgow, Scotland. Webcam and weather:- http://windycroft.co.uk/weather |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Inside humidity doesn't follow outside humidity | uk.sci.weather (UK Weather) | |||
100 Vehcles stuck on Bodmin Moor | uk.sci.weather (UK Weather) | |||
Relationship between humidity & dielectric constant, humidity & temperature, | sci.geo.meteorology (Meteorology) | |||
Davis Humidity problem :-0 | uk.sci.weather (UK Weather) | |||
Met Office radar stuck again | uk.sci.weather (UK Weather) |